DTC P0132 O2 SENSOR CIRCUIT HIGH VOLTAGE (BANK 1 SENSOR 1)
|
DTC P0132 O
2
SENSOR CIRCUIT HIGH
VOLTAGE (BANK 1 SENSOR 1)
|
Detect the open or short circuit of sensor.
Judge NG when the element impressed voltage
is out of range, or the element current is out of range.
(1)
|
Atmosphere
|
(A)
|
Electromotive
force
|
|
|
(2)
|
Exhaust
|
(B)
|
Air fuel
ratio
|
|
|
(3)
|
ZrO
2
|
(C)
|
Lean
|
|
|
(4)
|
Ceramic
heater
|
(D)
|
Rich
|
|
|
Secondary
Parameters
|
Enable
Conditions
|
Battery
voltage
|
≥ 10.9
V
|
Always perform the diagnosis continuously.
Judge NG when the continuous time of completing
any malfunction criteria below becomes more than 1 second.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Input voltage
|
≥ 3.8
V
|
Input
current
|
≥ 0.005
A
|
Time Needed for Diagnosis:
1
second
Malfunction Indicator
Light Illumination:
Illuminates as soon as the malfunction
occurs.
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
•
|
Front oxygen (A/F) sensor heater control:
Not allowed to turned on the heater.
|
•
|
A/F main learning: Not allowed
to calculate the A/F main learning compensation factor.
|
•
|
A/F sub learning: Not allowed
to calculate the A/F sub learning compensation factor.
|
•
|
Compensation when starting the engine
at high temperature: Make the MIN value to be 0 from 0.06 normally.
|
•
|
Purge control: Not allowed to purge.
|
ECM OPERATING
AT DTC SETTING
|
Memorize the freeze frame data. (For test
mode $02)