DTC P0327 KNOCK SENSOR 1 CIRCUIT LOW INPUT (BANK 1 OR SINGLE SENSOR)
|
DTC P0327 KNOCK SENSOR 1 CIRCUIT LOW INPUT
(BANK 1 OR SINGLE SENSOR)
|
Detect the open or short circuit of the knock
sensor. Judge NG when out of the standard value.
(1)
|
Case
|
(4)
|
Nut
|
(A)
|
To knock
sensor harness
|
(2)
|
Weight
|
(5)
|
Resistance
|
|
|
(3)
|
Piezoelectric
element
|
|
|
|
|
Secondary
Parameters
|
Enable
Conditions
|
None
|
|
Always perform the diagnosis continuously.
Abnormality Judgment
Judge NG when the continuous time of completing
the malfunction criteria below becomes more than 1 second.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Output
voltage
|
< 0.238
V
|
Ignition
switch
|
ON
|
Time Needed for Diagnosis:
1
second
Malfunction Indicator
Light Illumination:
Illuminates as soon as the malfunction
occurs.
Normality Judgment
Judge OK and clear NG when the malfunction
criteria below are completed.
Judgment
Value
Malfunction
Criteria
|
Threshold
Value
|
Output
voltage
|
≥ 0.25
V
|
Ignition
switch
|
ON
|
•
|
When the OK idling cycle was completed 40 times
in a row
|
•
|
When “Clear Memory” was
performed
|
MALFUNCTION
INDICATOR LIGHT CLEAR CONDITION
|
•
|
When the OK driving cycle was completed 3 times
in a row
|
•
|
When “Clear Memory” was
performed
|
Knock compensation:
•
|
At normal: Learned ignition timing value = knock
F/B timing value + whole learning timing value + partial learning
timing value.
|
•
|
At trouble: Learned ignition timing = −3°CA
(Retard 3°CA)
Knock F/B timing value = 0°CA
Whole learning is not allowed.
Partial learning is not allowed.
|
ECM OPERATING
AT DTC SETTING
|
Memorize the freeze frame data. (For test
mode $02)