INSPECTION
INSPECTION |
Terminal | Resistance |
Terminals
IGN and GND
|
208±10 Ω
|
Terminals
IGN and UNIT
|
56±10 Ω
|
Terminals
UNIT and GND
|
264±10 Ω
|
If NG, replace the water temperature gauge and fuel gauge assembly.
If OK, replace the combination meter printed circuit.