SAAB WIS ONLINE

PRE-RELEASE

B1680

Read the instructions below then start the fault diagnostic procedure.

Symptom: Soft top cannot be operated. SID shows message SOFT TOP FAILURE. Window lifts cannot be operated.

B1680


Valve/Relay Bus. Fault

Fault symptom

Soft top cannot be operated. SID shows message SOFT TOP FAILURE.

Window lifts cannot be operated.



Condition

Control module does not get response from any unit connected to VR-bus, that is, all units are missing.

Diagnostic procedure

There is communication on the VR-bus as long as there is +54-current. This DTC is generated if response is missing from all units on the VR-bus.

Cause of the problem may be:


- open circuit between control module pin 14 and crimp J159

- shorting to ground on bus

- internal shorting in a relay or valve


Check the voltage between the VR-bus+ and ground using a multimeter. The voltage should be approximately 4.3 V

Checking wiring harness

Intermittent faults can exist during temporary short circuits and open circuits. Wiggle the wiring harness at several points and in different directions to discover problems in the wiring harness and connectors. Observe the multimeter, diagnostic tool or the test lamp during checking.



PRE-RELEASE