SAAB WIS ONLINE

PRE-RELEASE

Coolant level switch (242)

Coolant level switch (242)

Location

Coolant level switch (242)

Main task

To warn of low coolant level.

If the coolant level is low, the float sinks, at which time the ring magnet actuates the reed, which closes the circuit. BCM transmits the bus message "Coolant level low".

Type



Magnetic reed actuated by a magnet situated in a float.

Connection

Pin No. Signal type Description
1 Signal BCM pin A(13) (K78)
2 Ground Via crimp J97 in grounding point G33S