Read the instructions below then start the fault diagnostic procedure.

Symptom: Soft top cannot be operated

  B1299 06


Soft Top Stowage Sensor Circuit, Open/Short to Ground

Fault symptom

Soft top cannot be operated

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module input voltage is below 0.2 V ±0.2 V

System reaction to a fault:

Soft top cannot be operated

Checking the wiring harness

Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Soft top storage obstructed
(See also description of readings/activations in diagnostic tool)