SAAB WIS ONLINE

PRE-RELEASE

Test readings, rear right door module, (702RR)

Test readings, rear right door module, (702RR)

Scope



The following pages contain directions and readings for testing signals and levels of the control module.

Remember


Observe the test criteria. Use common sense when assessing the test results.

Check first that the control module is receiving power and is grounded.

Then check all sensor inputs and signals from other systems.

Finally, check the control module outputs. Remember that the test readings are not a confirmation of whether the actuator is in working order.

If a test reading is incorrect, use the wiring diagram to locate the leads, connectors or components that need to be checked further.

Specified readings are for a calibrated Fluke 88/97.

Test readings % (+) and ms (+) indicate the signal pulse ratio and pulse width respectively. A scan tool with pulse ratio and pulse width measurement must be used. The sign indicates positive trigger pulse, TRIG+.


J1


Note

All units on the I and P-buses send signals.


Control module pin Component/ function IN/OUT Test criteria Measure across Test reading
1-3 Not connected
4 Ground, logic OUT Ignition ON 4-B+ B+
5 Power supply, hall sensor IN Ignition ON 6-(J2-7) 4.6-4.7V
6-8 Not connected
9 Hall sensor 2 IN Ignition ON Express activated 9-5 6.3-6.4 AC
10-12 Not connected
13 TSL sensor IN Ignition ON 13-(J2-7) 11V
14 Sensor, central locking system lock/unlock IN Ignition ON 14-(J2-7) 1.86V
15 Not connected
16 Hall sensor 1 IN Ignition ON Express activated 16-5 6.3-6.4 AC
17-18 Not connected
19 Central locking system, lock/unlock OUT Door closed, ignition OFF 19-(J2-7) Lock 12V for <0.2s Unlock 4.5V for <0.2s
20 +30 voltage logic IN Ignition ON 20-(J2-7) B+
21 Not connected
22 Ground, hall sensor OUT 22-5 4.76V
23 Central locking system, lock/unlock OUT Door closed, ignition OFF Door closed, lock 23-(J2-7) Lock 0.3V for <0.2s Unlock 12V for <0.2s
24 Sensor ground, central locking system OUT Ignition ON 24-32 4.10V
25 TSL activation OUT Door closed, ignition OFF Lock 6V for <0.2s Unlock 5.2V for <0.2s
26-27 Not connected
27 Courtesy lighting IN Ignition ON 27-(J2-7) B+
28 I-bus OUT Ignition ON Use 86 11 857 Test lamp, red/green 28-(J2-7) Test lamp should flash
29-31 Not connected
32 Door switch IN Ignition ON 32-(J2-7) 4.10V


J2

Note

All units on the I and P-buses send signals.



Control module pin Component/ function IN/OUT Test criteria Measure across Test reading
1 Window lift, up IN Ignition ON Close window 1-7 B+
2 Not connected
3 +30 voltage IN Ignition ON 3-7 B+
4 Not connected
5 Window lift, down IN Ignition ON Open window 5-7 B+
6 Not connected
7 Ground OUT Ignition ON 7-3 B+
8 Not connected


PRE-RELEASE