Control panel, manual climate control (504) .

Main task

The control panel processor receives information from the heating/air distribution knob potentiometers, calculates and ensures that the DC motors for heating/air distribution positions correspond to the selections made by the user.


Type

Contains a microprocessor, see MCC, general description . Is not connected to a bus.

Power supply, ground and bus communication

Pin Signal type Description
10 Power ground Power supply
17 +30 Power supply