Read the instructions below then start the fault diagnostic procedure.

Symptom: No express function. Electric window lift jerks during operation.

  B1008 41


Control Module not Added

Fault symptom

No express function.

Electric window lift jerks during operation.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module not configured.

System reaction to a fault:

No express function.
Electric window lift jerks during operation.

Diagnostic help

Control module was not added.

See "Procedure after fitting the control module"

Diagnostic help

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"