SAAB WIS ONLINE

PRE-RELEASE

RLDM / B1000 30

Read the instructions below then start the fault diagnostic procedure.

Symptom: Electric window lift cannot be operated.

  B1000 30


Control Module. Internal Fault

Fault symptom

Electric window lift cannot be operated.

On-board diagnosis

Type of diagnosis:

Diagnostics run each time control module "wakes".

Enable criteria:

Ignition ON.

Fault criteria:

Internal control module fault

System reaction to a fault:

Electric window lift cannot be operated.

Diagnostic help

Change the control module.

See "Procedure for control module replacement"

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"

PRE-RELEASE