SAAB WIS ONLINE

PRE-RELEASE

T8 / P0695 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Radiator fan malfunction. No A/C function. Torque Reduction

  P0695 00


Cooling Fan 3 Control Circuit, Opn/Short to Ground

Fault symptom

Radiator fan malfunction.

No A/C function.

Torque Reduction

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Engine running.
Output is not active.

Fault criteria:

When voltage on the output is below 2.0 V for more than 1 s.

Dependent:

None

System reaction to a fault:

Switches off output to A/C relay.
Engine torque limitation (which is a function of vehicle speed, intake air temperature and number of incorrect fan stages).

OK report:

Fault criteria NOT fulfilled for 5 s.

Fault handling:

Type III without Check Engine.
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fan Control Output 3

Activation:
Radiator Fan Speed 4
(See also description of readings/activations in diagnostic tool)

PRE-RELEASE