SAAB WIS ONLINE

PRE-RELEASE

Switch, hazard flashers (25)

Switch, hazard flashers (25)

Location

Switch, hazard flashers (25)


Main task

Used to activate hazard warning lights and to indicate that they are active. BCM transmits the function status on the bus.

Type

The button is single-pin, has a return spring and closes to ground when depressed. The button also contains an indicator lamp that is grounded internally.

Connection

The lead to the button is supplied 10.2 V via a BCM integrated resistor of 1.5 kΩ. Control module inputs are digital; voltage over 2V is interpreted as an open circuit while voltage lower than 2V is interpreted as closed.



The indicator lamp in the button is supplied battery voltage from BCM in order to light.

Pin No.
Signal type
Description
13 Ground ACC control module's ground connection in the body
3 Supply from BCM From BCM pin B61 (K78), the pin is grounded when it is pressed in
2 Supply from BCM Supply to indicator lamp from BCM pin A17 (K78)


PRE-RELEASE