Control module calibration AHL/AFL

Check the following points before starting calibration.


- The car should be level.

- The car should be unloaded.

- Check that the light image has not been reset to the right-hand/left-hand traffic "tourist solution"

- Stabilise the suspension by rocking the car.

- The handbrake must not be applied.

- Steering wheel and wheels in straight-ahead position.

- Ignition in ON position

- The Xenon lamps should be lit.

- Battery voltage must be >10.5 V.


Connect the diagnostic tool and calibrate the AHL/AFL control module.

Check the function of the headlamps and clear any DTCs.

Check the light setting and adjust as necessary, see Light setting, headlamps / Light setting, headlamps (US/CA) .