SAAB WIS ONLINE

PRE-RELEASE

PSM / B1765 04

Read the instructions below then start the fault diagnostic procedure.

Symptom: Memory functions not working

  B1765 04


Height Motor Output Circuit, Open

Fault symptom

Memory functions not working

On-board diagnosis

Type of diagnosis:

Continually when the engine is run.

Enable criteria:

When seat operation is permitted.

Fault criteria:

MOTOR UP

Voltage on the control module output is below 6 ±0.2V.
MOTOR DOWN

Voltage on the control module output is below B+ -0.7V.

System reaction to a fault:

No memory functions work
Output is switched off, tries however to activate the engine once each time the ignition is switched on.

OK report:

Fault criteria NOT fulfilled.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activate:
Motor, Height Up
Motor, Height Down
(See also description of readings/activations in diagnostic tool)

PRE-RELEASE