Grounding point G34S

Grounding point G34S


Location: At the floor below the right A-pillar (BK/WH cable)

The grounding point is connected to the G43 grounding point via crimp connectors J108 and J80.

Connected components

Via Crimp connection J108, main wiring harness
102 Relay, fuel pump
702FR Control module, front door, RH
702RR Rear right door module (RRDM)
Via Crimp J135, inner door wiring harness in the front right door, which is connected to crimp J108
209FR Lamp, front right door courtesy lighting
388 Switch, tailgate/boot lid
514FR Switch, simultaneous central locking, front right door
Via Crimp connection J117, main wiring harness which is connected with crimp J108, cable screening for I-bus connection


Crimp J108


Connection to G43