SAAB WIS ONLINE

PRE-RELEASE

Position sensor, first bow locked, (561c)

Position sensor, first bow locked, (561c)

Location

Position sensor, first bow locked (561c)


Main task

The sensor gives information to the STC control module on the state of the first bow lock, locked or unlocked.

Unlocked


Locked


Type

Hall sensor with inbuilt magnet.

Technical data

Connection

Pin No. Signal type Description
2 Power supply B+ From the control module, STC
3 Signal output First bow locked (sensor affected) = 0.4-1.2 V First bow unlocked (sensor unaffected) = 2.4-3.4 V



The sensor is connected to the STC control module with two leads. The sensor is energized with B+ on pin 2 and gives information to the STC control module on pin 3.

The sensor is affected by the locking mechanism for the first bow. The sensor is affected when the first bow is locked.

Diagram