SAAB WIS ONLINE

PRE-RELEASE

AFL / B3440 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display. Headlamp beam adjustment not working.

  B3440 00


Right Stepper Motor, Malfunction

Fault symptom

Message appears in display.

Headlamp beam adjustment not working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Xenon lights on.
Stepping motor activated.
Battery voltage greater than 9 V.

Fault criteria:

Short-circuited to B+ or B-.
Open circuit
Temperature Error

System reaction to a fault:

Control module outputs to stepping motor switched off.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Before fault diagnosis begins, read the document "Safety and handling directions, xenon lights" under Technical description.

PRE-RELEASE