SAAB WIS ONLINE

PRE-RELEASE

ACC / B0175 02

Read the instructions below then start the fault diagnostic procedure.

  B0175 02


Mixed Air Sensor Left. Short to Ground



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Control module output voltage exceeds 0.2 V.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

In case of a fault, the control module will use the value from the mixed air temperature sensor, left-hand floor.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Air Mix Temperature Sensor Left Vent
Air Mix Temperature Left Vent
Air Mix Temperature Sensor Left Floor
Air Mix Temperature Left Floor
(See also description of readings/activations in diagnostic tool)

PRE-RELEASE