SAAB WIS ONLINE

PRE-RELEASE

CIM / B1000 35

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display. Cannot turn key. Engine does not start. Steering column lock not working.

  B1000 35


Control Module. Internal Fault

Fault symptom

Message appears in display.

Cannot turn key.

Engine does not start.

Steering column lock not working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Key in ignition switch.
Diagnosis takes 65 minutes. If the control module enters into standby before diagnosis is complete, diagnosis is resumed the next time the control module wakes.

Fault criteria:

Control module on-board diagnostics has detected a ROM error.

System reaction to a fault:

The control module does not allow starter motor cranking.
Steering column lock deactivated.

Diagnostic help

See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"