SAAB WIS ONLINE

PRE-RELEASE

DSM / B3920 61

Read the instructions below then start the fault diagnostic procedure.

Symptom: Memory functions not working Output is switched off, tries however to activate the engine once each time the ignition is switched on.

  B3920 61


Group 1 Motor Output Circuit, Relay Stuck to Ground

Fault symptom

Memory functions not working

Output is switched off, tries however to activate the engine once each time the ignition is switched on.

On-board diagnosis

Type of diagnosis:

Immediately after a soft start is completed.

Enable criteria:

When seat operation is permitted.

Fault criteria:

When voltage on output is below 0.5 V.

System reaction to a fault:

No memory functions work
Output is switched off, tries however to activate the engine once each time the ignition is switched on.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.