Read the instructions below then start the fault diagnostic procedure.

Symptom: Incorrect end position (electric window lift).

  B1000 36


Control Module. Internal Fault

Fault symptom

Incorrect end position (electric window lift).

On-board diagnosis

Type of diagnosis:

Diagnostics run each time control module "wakes".

Enable criteria:

When new data written to memory.

Fault criteria:

Control module on-board diagnostics has detected a EEPROM error.

System reaction to a fault:

Basic value from ROM used.

Diagnostic help

Change the control module.

See "Procedure for control module replacement"

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"