SAAB WIS ONLINE

PRE-RELEASE

T8 / P0202 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Engine misfires or does not start.

  P0202 00


Injector 2 Circuit, Open/Short

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Engine misfires or does not start.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Main relay voltage exceeds 6V.
Starter motor cranking or engine running.

Fault criteria:

When voltage on output is below 5.5V when inactive or exceeds 5.5V when active.

Dependent:

None

System reaction to a fault:

Closed loop is blocked.
Fuel adaption is blocked.

OK report:

Fault criteria NOT fulfilled for 2 s.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation of output for injector 2.
(See also description of readings/activations in diagnostic tool)