The following table indicates the calibration interval for various gauges/instruments.

Designation Part no. Calibration standard
Belt tension gauge 83 93 985 CL 2.5. See separate table below.
Dial indicator 78 40 622 JIS B 7503
Cooling pressure tester, non-adjustable (16) 30 05 477 ET 09 STD 12 01 43
VIP indicator 87 92 194 DIN 878-2270
Dial indicator for toe-in 88 19 062 Internal standard. Can only be calibrated by the supplier.


Conversion table for calibrating the belt tension gauge

Torque (Nm) Pressure (bar)
100 0.65
200 0.95
300 1.25
400 1.54
500 1.85
600 2.15
700 2.45
800 2.75
900 3.04


Calibration interval : Once every other year.