Read the instructions below then start the fault diagnostic procedure.

Symptom: Memory functions not working Seat can jerk during start and stop.

  B2375 04


Slide Position Sensor Circuit, Open

Fault symptom

Memory functions not working

Seat can jerk during start and stop.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Turn Ignition On

Fault criteria:

When control module input exceeds 0.5 V.

System reaction to a fault:

No memory functions work
The control module loses end position calibration for the motor in question.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Slide Sensor
Slide Position
(See also description of readings/activations in diagnostic tool)