SAAB WIS ONLINE

PRE-RELEASE

Mode Control Cam Actuator Replacement

Mode Control Cam Actuator Replacement



Callout Component Name

Preliminary Procedures

1. Disconnect the negative battery cable. Refer to: Battery, negative cable, disconnecting and connecting .

2. Remove LH floor air outlet duct. Refer to Floor Rear Air Outlet Duct Replacement - Left Side .


1 Mode Cam Actuator Cover Screw (Qty: 1) Refer to Fastener Caution .

Procedure

Disconnect the mode actuator electrical connector.

Tighten

1.5 Nm (13 lb in)
2 Mode Cam Actuator Cover.
3 Mode Cam Actuator Gears
4 Mode Cam Actuator Screw (Qty: 2)

Tighten

1.5 Nm (13 lb in)
5 Mode Cam Actuator
Note

Actuator is self-calibrating when connecting the battery.