Solenoids

To remove

Important

Solenoids SLT, SLS and SLU that control the system pressure and Lock-up must not be dismantled!



1. Remove the valve housing cover .

2. Unplug the relevant solenoid's connector.


3. Remove the solenoid's retaining bolt.

4. Prise the solenoid loose, using a screwdriver.


Fitting


1. Position the solenoid and tighten the bolt.

Tightening torque: 7 Nm (5 lbf ft).


2. Plug in the solenoid's connector.

3. Fit the valve housing cover .