SAAB WIS ONLINE

PRE-RELEASE

Refrigerant System Specifications

Refrigerant System Specifications

Application Specification
Metric English
Abrupt refrigerant loss

60 ml¹

2.0 oz¹

When charging system after recovery

20 ml

0.7 oz

Compressor Replacement

Note

Compressor failure can occur if the oil removed during refrigerant recovery is not replaced.


The service compressor is shipped with a specified amount of PAG oil.

Compressor oil (Sanden PXE16)

110 ml

3.7 oz

Compressor Oil (Delphi SP17)

150 ml

5.0 oz

Condenser Replacement

30 ml 2

1.0 oz 2

Evaporator Replacement

40 ml 2

1.3 oz 2

Any Line Set (Hose/Tube or Tube Assembly) Replacement

20 ml 2

0.7 oz 2

Total System PAG Oil Capacity - Sanden

110.0 ml

3.7 oz

Total System PAG Oil Capacity - Delphi

150 ml

5.0 oz

R-134a

Refrigerant Charge (R-134a)

0.68 kg

1.5 lb

¹ Abrupt refrigerant loss due to large leak, hose rupture, collision, or pressure relief valve opening. Conditions that allow the refrigerant to seep or bleed off over time do not cause this oil loss. Upon replacement of a component that caused a large refrigerant loss, also add the required amount of oil for the particular component.

2 If more than the specified amount of PAG oil was drained from a component, add the amount drained.



PRE-RELEASE