Base Engine Misfire with Abnormal Valve Train Noise


Cause Correction
Worn or loose rocker arms

The rocker arm bearing end caps and/or needle bearings should intact within the rocker arm assembly.

Replace the valve rocker arms as required.

Stuck valves

Carbon buildup on the valve stem can cause the valve not to close properly.

Repair or replace as required.

Excessively worn or mis-aligned timing chain

Replace the timing chain and sprockets, as required.

Worn camshaft lobes

Replace the camshaft and valve lash adjusters.

Sticking lifters

Replace as necessary.