SAAB WIS ONLINE

PRE-RELEASE

DTC B0223, B022A, B0233, B023A, B0408, B0418, B0428, or B3531

DTC B0223, B022A, B0233, B023A, B0408, B0418, B0428, or B3531

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions provides an overview of each diagnostic category.


DTC Descriptors

DTC B0223 01

Recirculate Position Command 1 Circuit Short to Battery

DTC B0223 06

Recirculate Position Command 1 Circuit Low Voltage/Open

DTC B022A 01

Recirculate Position Command 2 Circuit Short to Battery

DTC B022A 06

Recirculate Position Command 2 Circuit Low Voltage/Open

DTC B0233 01

Air Flow Control Circuit Short to Battery

DTC B0233 06

Air Flow Control Circuit Low Voltage/Open

DTC B023A 02

HVAC Actuators Supply Voltage Short to Ground

DTC B0408 01

Main Temperature Control Circuit Short to Battery

DTC B0408 06

Main Temperature Control Circuit Low Voltage/Open

DTC B0418 01

Right Temperature Control Circuit Short to Battery

DTC B0418 06

Right Temperature Control Circuit Low Voltage/Open

DTC B0428 01

Rear Temperature Control Circuit Short to Battery

DTC B0428 06

Rear Temperature Control Circuit Low Voltage/Open

DTC B3531 01

Air Flow Control Rear Circuit Short to Battery

DTC B3531 06

Air Flow Control Rear Circuit Low Voltage/Open

Diagnostic Fault Information

Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Stepper Motors 12V Reference

B023A 02, B0223 06, B022A 06, B0233 06, B0408 06, B0418 06, B0428 06, B3531 06

B0223 06, B022A 06, B0233 06, B0408 06, B0418 06, B0428 06, B3531 06

-

-

Recirculation Actuator Control 1

B0223 06

B0223 06

B0223 01

1

Recirculation Actuator Control 2

B0223 06

B0223 06

B0223 01

1

Recirculation Actuator Control 3

B0223 06

B0223 06

B0223 01

1

Recirculation Actuator Control 4

B0223 06

B0223 06

B0223 01

1

Air Temperature Actuator - Left Control 1

B0408 06

B0408 06

B0408 01

2

Air Temperature Actuator - Left Control 2

B0408 06

B0408 06

B0408 01

2

Air Temperature Actuator - Left Control 3

B0408 06

B0408 06

B0408 01

2

Air Temperature Actuator - Left Control 4

B0408 06

B0408 06

B0408 01

2

Air Temperature Actuator - Right Control 1

B0418 06

B0418 06

B0418 01

2

Air Temperature Actuator - Right Control 2

B0418 06

B0418 06

B0418 01

2

Air Temperature Actuator - Right Control 3

B0418 06

B0418 06

B0418 01

2

Air Temperature Actuator - Right Control 4

B0418 06

B0418 06

B0418 01

2

Mode Actuator Control 1

B0233 06

B0233 06

B0233 01

3

Mode Actuator Control 2

B0233 06

B0233 06

B0233 01

3

Mode Actuator Control 3

B0233 06

B0233 06

B0233 01

3

Mode Actuator Control 4

B0233 06

B0233 06

B0233 01

3

Air Inlet Actuator Control 1

B022A 06

B022A 06

B022A 01

1

Air Inlet Actuator Control 2

B022A 06

B022A 06

B022A 01

1

Air Inlet Actuator Control 3

B022A 06

B022A 06

B022A 01

1

Air Inlet Actuator Control 4

B022A 06

B022A 06

B022A 01

1

Rear Air Temperature Actuator Control 1

B0428 06

B0428 06

B0428 01

4

Rear Air Temperature Actuator Control 2

B0428 06

B0428 06

B0428 01

4

Rear Air Temperature Actuator Control 3

B0428 06

B0428 06

B0428 01

4

Rear Air Temperature Actuator Control 4

B0428 06

B0428 06

B0428 01

4

Rear Mode Actuator Control 1

B3531 06

B3531 06

B3531 01

5

Rear Mode Actuator Control 2

B3531 06

B3531 06

B3531 01

5

Rear Mode Actuator Control 3

B3531 06

B3531 06

B3531 01

5

Rear Mode Actuator Control 4

B3531 06

B3531 06

B3531 01

5

1. Air Recirculation Malfunction

2. Air Temperature Malfunction

3. Air Distribution Malfunction

4. Auxiliary Air Temperature Malfunction

5. Air Delivery Improper - Auxiliary



Circuit/System Description

Stepper motors are used for temperature regulation, air distribution control and recirculation flap control.

With the appropriate switches at the Radio/HVAC control, the desired air temperature flap position, air distribution flap position and recirculation flap position can be put in. The selected values are passed to the HVAC control module via the LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motors and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motors put the appropriate flap into the calculated position, in order to reach the put in temperature/position.

Conditions for Running the DTC


Ignition ON.

The HVAC control module is ON.


Conditions for Setting the DTC

B023A 02

The stepper motors supply output is shorted to ground.

B0223 01, B022A 01, B0233 01, B0408 01, B0418 01, B0428 01 or B3531 01

At least one control output (of four possible outputs) of the appropriate stepper motor is shorted to voltage when motor starts moving. Faults are not detected when motor is already running or target position is already reached.

B0223 06, B022A 06, B0233 06, B0408 06, B0418 06, B0428 06 or B3531 06

At least one control output (of four possible outputs) of the appropriate stepper motor is shorted to ground or open when motor starts moving. Faults are not detected when motor is already running or target position is already reached.

Action Taken When the DTC Sets


B023A 02

The affected output will be switched off for hardware protection.

All stepper motors are deactivated.



B0223, B022A, B0233, B0408, B0418, B0428 or B3531

The affected output will be switched off for hardware protection.

The affected stepper motor is deactivated.


Conditions for Clearing the DTC

The condition for setting the DTC is no longer present.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Automatic HVAC Description and Operation

Electrical Information Reference


Circuit Testing

Connector Repairs

Testing for Intermittent Conditions and Poor Connections

Wiring Repairs


Scan Tool Reference

Control Module References for scan tool information

Circuit/System Verification


1. Verify that DTC B023A 02 is not present.

2. If DTC is present, refer to Actuator Power Supply Malfunction.

3. Verify that DTC B0223 01 or B0223 06 is not present.

4. If DTC is present, refer to Recirculation Actuator Malfunction.

5. Verify that DTC B022A 01 or B022A 06 is not present.

6. If DTC is present, refer to Air Inlet Actuator Malfunction.

7. Verify that DTC B0233 01 or B0233 06 is not present.

8. If DTC is present, refer to Mode Actuator Malfunction.

9. Verify that DTC B0408 01 or B0408 06 is not present.

10. If DTC is present, refer to Air Temperature Actuator - Left Malfunction.

11. Verify that DTC B0418 01 or B0418 06 is not present.

12. If DTC is present, refer to Air Temperature Actuator - Right Malfunction.

13. Verify that DTC B0428 01 or B0428 06 is not present.

14. If DTC is present, refer to Rear Air Temperature Actuator Malfunction.

15. Verify that DTC B3531 01 or B3531 06 is not present.

16. If DTC is present, refer to Rear Mode Actuator Malfunction.


Circuit/System Testing


Actuator Power Supply Malfunction

1. Ignition OFF, disconnect the X3 harness connector at the K33 HVAC Control Module.

2. Test for infinite resistance between the reference voltage circuit terminal 15 X3 and ground

3. If less than the specified value, test the reference voltage circuit for a short to ground.

4. Test for infinite resistance between the reference voltage circuit terminal 10 X4 and ground

5. If less than the specified value, test the reference voltage circuit for a short to ground.

6. If all circuits test normal, test or replace the K33 HVAC Control Module.



Recirculation Actuator Malfunction

1. Ignition OFF, disconnect the X3 harness connector at the K33 HVAC Control Module and at the M46 Air Recirculation Door Motor.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal at the K33 HVAC Control Module harness connector listed below and ground:

Terminal 16 X3

Terminal 17 X3

Terminal 18 X3

Terminal 19 X3

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal at the K33 HVAC Control Module harness connector listed below and ground:

Terminal 16 X3

Terminal 17 X3

Terminal 18 X3

Terminal 19 X3

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M46 Air Recirculation Door Motor terminal 1 and terminal 16 X3 at the K33 HVAC Control Module harness connector

M46 Air Recirculation Door Motor terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector

M46 Air Recirculation Door Motor terminal 3 and terminal 17 X3 at the K33 HVAC Control Module harness connector

M46 Air Recirculation Door Motor terminal 4 and terminal 18 X3 at the K33 HVAC Control Module harness connector

M46 Air Recirculation Door Motor terminal 6 and terminal 19 X3 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M46 Air Recirculation Door Motor and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Air Inlet Actuator Malfunction

1. Ignition OFF, disconnect the X3 and the X4 harness connector at the K33 HVAC Control Module and at the M4 Air Inlet Actuator.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 1 X4

Terminal 2 X4

Terminal 3 X4

Terminal 4 X4

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 1 X4

Terminal 2 X4

Terminal 3 X4

Terminal 4 X4

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M4 Air Inlet Actuator terminal 1 and terminal 1 X4 at the K33 HVAC Control Module harness connector

M4 Air Inlet Actuator terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector

M4 Air Inlet Actuator terminal 3 and terminal 2 X4 at the K33 HVAC Control Module harness connector

M4 Air Inlet Actuator terminal 4 and terminal 3 X4 at the K33 HVAC Control Module harness connector

M4 Air Inlet Actuator terminal 6 and terminal 4 X4 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M4 Air Inlet Actuator and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Mode Actuator Malfunction

1. Ignition OFF, disconnect the X3 harness connector at the K33 HVAC Control Module and at the M37 Mode Door Actuator.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 2 X3

Terminal 3 X3

Terminal 4 X3

Terminal 5 X3

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 2 X3

Terminal 3 X3

Terminal 4 X3

Terminal 5 X3

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M37 Mode Door Actuator terminal 1 and terminal 2 X3 at the K33 HVAC Control Module harness connector

M37 Mode Door Actuator terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector

M37 Mode Door Actuator terminal 3 and terminal 3 X3 at the K33 HVAC Control Module harness connector

M37 Mode Door Actuator terminal 4 and terminal 4 X3 at the K33 HVAC Control Module harness connector

M37 Mode Door Actuator terminal 6 and terminal 5 X3 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M37 Mode Door Actuator and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Air Temperature Actuator - Left Malfunction

1. Ignition OFF, disconnect the X3 harness connector at the K33 HVAC Control Module and at the M6L Air Temperature Door Actuator - Left.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 11 X3

Terminal 12 X3

Terminal 13 X3

Terminal 14 X3

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 11 X3

Terminal 12 X3

Terminal 13 X3

Terminal 14 X3

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M6L Air Temperature Door Actuator - Left terminal 1 and terminal 11 X3 at the K33 HVAC Control Module harness connector

M6L Air Temperature Door Actuator - Left terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector

M6L Air Temperature Door Actuator - Left terminal 3 and terminal 12 X3 at the K33 HVAC Control Module harness connector

M6L Air Temperature Door Actuator - Left terminal 4 and terminal 13 X3 at the K33 HVAC Control Module harness connector

M6L Air Temperature Door Actuator - Left terminal 6 and terminal 14 X3 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M6L Air Temperature Door Actuator - Left and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Air Temperature Actuator - Right Malfunction

1. Ignition OFF, disconnect the X3 and the X4 harness connector at the K33 HVAC Control Module and at the M6R Air Temperature Door Actuator - Right.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 5 X4

Terminal 6 X4

Terminal 7 X4

Terminal 8 X4

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 5 X4

Terminal 6 X4

Terminal 7 X4

Terminal 8 X4

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M6R Air Temperature Door Actuator - Right terminal 1 and terminal 5 X4 at the K33 HVAC Control Module harness connector

M6R Air Temperature Door Actuator - Right terminal 2 and terminal 15 X3 at the K33 HVAC Control Module harness connector

M6R Air Temperature Door Actuator - Right terminal 3 and terminal 6 X4 at the K33 HVAC Control Module harness connector

M6R Air Temperature Door Actuator - Right terminal 4 and terminal 7 X4 at the K33 HVAC Control Module harness connector

M6R Air Temperature Door Actuator - Right terminal 6 and terminal 8 X4 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M6R Air Temperature Door Actuator - Right and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Rear Air Temperature Actuator Malfunction

1. Ignition OFF, disconnect the X4 harness connector at the K33 HVAC Control Module and at the M37B Mode Door Actuator - Auxiliary.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 17 X4

Terminal 18 X4

Terminal 19 X4

Terminal 20 X4

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 17 X4

Terminal 18 X4

Terminal 19 X4

Terminal 20 X4

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M37B Mode Door Actuator - Auxiliary terminal 1 and terminal 17 X4 at the K33 HVAC Control Module harness connector

M37B Mode Door Actuator - Auxiliary terminal 2 and terminal 10 X4 at the K33 HVAC Control Module harness connector

M37B Mode Door Actuator - Auxiliary terminal 3 and terminal 18 X4 at the K33 HVAC Control Module harness connector

M37B Mode Door Actuator - Auxiliary terminal 4 and terminal 19 X4 at the K33 HVAC Control Module harness connector

M37B Mode Door Actuator - Auxiliary terminal 6 and terminal 20 X4 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M37B Mode Door Actuator - Auxiliary and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.



Rear Mode Actuator Malfunction

1. Ignition OFF, disconnect the X4 harness connector at the K33 HVAC Control Module and at the M6B Air Temperature Door Actuator - Auxiliary.

2. Ignition ON, test for less than 0.3 V between the control circuit terminal listed below and ground:

Terminal 13 X4

Terminal 14 X4

Terminal 15 X4

Terminal 16 X4

3. If greater than the specified value, test the control circuit for a short to voltage.

4. Ignition OFF, test for infinite resistance between the control circuit terminal listed below and ground:

Terminal 13 X4

Terminal 14 X4

Terminal 15 X4

Terminal 16 X4

5. If less than the specified value, test the control circuit for a short to ground.

6. Test for less than 5 Ω between the control circuit terminals listed below:

M6B Air Temperature Door Actuator - Auxiliary terminal 1 and terminal 13 X4 at the K33 HVAC Control Module harness connector

M6B Air Temperature Door Actuator - Auxiliary terminal 2 and terminal 10 X4 at the K33 HVAC Control Module harness connector

M6B Air Temperature Door Actuator - Auxiliary terminal 3 and terminal 14 X4 at the K33 HVAC Control Module harness connector

M6B Air Temperature Door Actuator - Auxiliary terminal 4 and terminal 15 X4 at the K33 HVAC Control Module harness connector

M6B Air Temperature Door Actuator - Auxiliary terminal 6 and terminal 16 X4 at the K33 HVAC Control Module harness connector

7. If greater than the specified value, test the control circuit for an open/high resistance.

8. If all circuits test normal, replace the M6B Air Temperature Door Actuator - Auxiliary and verify the DTC does not reset.

9. If the DTC resets, replace the K33 HVAC Control Module.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


Temperature Valve Actuator Replacement - Left Side (Right Hand Drive) Temperature Valve Actuator Replacement - Left Side (Left Hand Drive)

Temperature Valve Actuator Replacement - Right Side (Left Hand Drive)

Mode Control Cam Actuator Replacement (Right Hand Drive) Mode Control Cam Actuator Replacement (Left Hand Drive)

Air Inlet Valve Actuator Replacement (Right Hand Drive) Air Inlet Valve Actuator Replacement (Left Hand Drive)

Inside Air Valve Actuator Replacement (Right Hand Drive)

Auxiliary Temperature Valve Actuator Replacement

Auxiliary Mode Valve Actuator Replacement

Control Module References for HVAC control module replacement, setup, and programming


PRE-RELEASE