SAAB WIS ONLINE

PRE-RELEASE

DTC 64 or 65

DTC 64 or 65

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions provides an overview of each diagnostic category.


DTC Descriptors

DTC 64

Parking Heater Combustion Sensor Circuit Open

DTC 65

Parking Heater Combustion Sensor Circuit Low or Circuit High

Diagnostic Fault Information

Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Parking Heater Combustion Sensor Signal

65

64

65

-

Parking Heater Combustion Sensor Low Reference

-

64

65

-



Circuit/System Description

The fuel operated heater uses a combustion sensor to monitor combustion temperature.

Conditions for Running the DTC

Ignition OFF. Battery voltage must be between 10-15 V.

Conditions for Setting the DTC

Fuel operated heater has recognized out of range condition for more than 2.5 s.

Action Taken When the DTC Sets

The fuel operated heater will lock.

Conditions for Clearing the DTC

DTC must be cleared with the remote control.

Reference Information

Schematic Reference

HVAC Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Fuel Operated Heater Description and Operation

Electrical Information Reference


Circuit Testing

Connector Repairs

Testing for Intermittent Conditions and Poor Connections

Wiring Repairs


Circuit/System Verification

Ignition OFF, command the parking heater ON and OFF with the remote control. Verify the parking heater turns ON and OFF with no DTCs.

Circuit/System Testing


1. Ignition OFF, parking heater OFF, separate the K87 Parking Heater Control Module from the X150 Parking Heater Harness & Parking Heater Assembly Harness.

2. Test the B167 Parking Heater Combustion Sensor by varying the sensor temperature while monitoring the sensor resistance. Compare the readings with the Fuel Operated Heater Sensor Resistance Table and verify that the resistance is within 5% of the specification.

3. If not within the specified range, replace the B167 Parking Heater Combustion Sensor.

4. If the B167 Parking Heater Combustion Sensor tests normal, replace the K87 Parking Heater Control Module.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

PRE-RELEASE