SAAB WIS ONLINE

PRE-RELEASE

DTC B252A or B252B

DTC B252A or B252B

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions has overviews of all diagnostic categories.


DTC Descriptors

DTC B252A 01

Driver Door Unlatch Enable Circuit Short to Battery

DTC B252B 01

Passenger Door Unlatch Enable Circuit Short to Battery

Circuit/System Description

The keyless entry control module receives a discrete input from the driver and passenger door open switch signal circuits. The driver window motor or driver window switch receives a discrete input from the driver door ajar switch signal circuit. The passenger window switch receives a discrete input from the passenger door ajar switch signal circuit. The door ajar switches are integrated in the lock unit of the respective door. When a door is opened, the normally open door open and door ajar switch closes. With the door open switch closed, ground is provided to the door open switch signal circuit. The window switches communicate the door ajar data via serial data communication with the keyless entry control module.

Conditions for Running the DTC

Battery voltage is between 9-16 V.

Conditions for Setting the DTC

B252A 01

The keyless entry control module detects a short to voltage on the driver door unlatch enable circuit for 30 s.

B252B 01

The keyless entry control module detects a short to voltage on the driver door unlatch enable circuit for 30 s.

Action Taken When the DTC Sets

The keyless entry control module ignores inputs from the exterior door handle switches.

Conditions for Clearing the DTC


This DTC will be current for as long as the fault is present.

When the fault is no longer present, the DTC will be a history DTC.

A history DTC will clear after 50 ignition cycles.


Reference Information

Schematic Reference

Release Systems Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Power Door Latch Description and Operation

Electrical Information Reference


Circuit Testing

Connector Repairs

Testing for Intermittent Conditions and Poor Connections

Wiring Repairs


Scan Tool Reference

Control Module References for information on diagnostic tools

Circuit/System Testing


1. Ignition OFF, disconnect the harness connector at the malfunctioning door latch assembly.

2. Ignition ON, verify that a test lamp does not illuminate between the control circuit terminal 5 and ground.

3. If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal replace the K84 Keyless Entry Control Module.

4. Verify that a test lamp does not illuminate between the control circuit terminal 10 and ground.

5. If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal replace the K84 Keyless Entry Control Module.

6. If all circuits test normal, replace the door latch assembly.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


Front Side Door Lock Replacement

Control Module References for keyless entry control module replacement, setup and programming