SAAB WIS ONLINE

PRE-RELEASE

P1664

Symptom: SHIFT UP lamp on continuously or out of order.

P1664

SHIFT UP

Fault symptoms

SHIFT UP lamp on continuously or out of order.

Conditions

P1664


Break

Short circuit to ground/battery positive (B+).


Diagnostic help

The SHIFT UP lamp can be activated with the ISAT scan tool.


- Select "ACTIVATE".

- Select "SHIFT UP LAMP".


The command activates the lamp at a frequency of 0.5 Hz for 30 seconds.

Check the wiring

Intermittent faults may occur as a result of temporary short circuits and breaks in the wiring. Jiggle the wiring at several points and in different directions to ascertain whether the wiring harness, including any connectors, is causing the trouble. Observe the multimeter, ISAT scan tool or test lamp while doing this.

Diagnostic procedure

1. Check the bulb




- Check whether the light bulb is OK.


Is the bulb OK?

yes

Continue with point 2.


no

Change the light bulb. Continue with point 3.


2. Check the control module connection



- Unplug the main instrument display panel's connector.

- Connect the test lamp to:

- Connect the ISAT Scan Tool.

- Turn the ignition switch to the ON position.

- Select "ACTIVATE".

- Select "SHIFT UP LAMP".


The test lamp should flash at a frequency of 0.5 Hz for 30 seconds.

Test lamp flashing?

yes

Continue fault diagnosis as described in "electrical system, main instrument display panel" .


no

Check and if necessary repair or replace the lead between pin 39 of the main instrument display panel's connector and pin 35 of the Motronic control module's connector. Continue with point 3.


3. Final check



- Clear the diagnostic trouble code.

- Implementation of driving cycle:

- Evaluation of driving cycle:


Has the diagnostic trouble code recurred?

yes

Continue as described in .


no

The steps taken to rectify the fault were correct.


PRE-RELEASE