1. Check the battery voltage on generator 2.

2. Inspect fuse 17 and check that it is supplied with current.

3. Check that the charging lamp bulb is intact.

4. Check connectors and the wiring harness as well as the generator's ground connection.

5. Check that terminal D+ on the generator is supplied with current.

6. Start the engine and take a voltage reading across B+ on the generator and ground. Also take a voltage reading across D+ on the generator and ground. The difference between the two readings obtained should not exceed 0.7 V.