SAAB WIS ONLINE

PRE-RELEASE

Menu "Read Values"

Menu "Read Values"

Text

Unit

Min.

Max.

Description

Outdoor Temperature

°C

-40

80

Read the unfiltered value for the outdoor temperature.



Outdoor Temperature, Filtered

°C

-40

80

The SID unit's internal filtered value for outdoor temperature. Filtering takes place as follows:


+1°C change every 6 minutes at speeds below 30 km/h.

+1°C change every 30 seconds at speeds above 30 km/h.

-1°C change every 2.5 seconds.


Rheostat Sensor

Volt

0

05.00

Voltage across the resistor in the rheostat. The voltage changes linearly from 0 V (max. rheostat level) to approx. 3.5 V (min. rheostat level).

Rheostat, Filtered

%

0

100

Rheostat value, converted internally into %


When the main light switch is OFF, the rheostat value is 0%.

When the main light switch is ON, the rheostat value can be varied 0-100%.


Rheostat Night Panel, Filtered

%

0

100

Rheostat value, converted internally into %, reduced by a fixed value.

LCD Dimmer Value, Filtered

%

0

100

Lighting value for display converted internally into %. The value is calculated from the rheostat level and the level of the light intensity in the car.

Indoor Light Sensor Value

%

0

100

Value from light sensor for interior light intensity in %.

Indoor Light Intensity, Filtered

lux

0

1200

The SID unit's internal filtered value for interior light intensity.

Steering Wheel Control

Volt

0

05.00

The steering wheel buttons consist of 7 resistors connected in series and supplied with +5 V from the SID unit.

When a button is pressed, the resistor concerned is grounded, giving the relevant voltage. See for voltage values.

On cars without steering wheel buttons only the voltage for the horn button is applicable.

Steering Wheel Buttons

NONE

NXT

DOWN

UP

SRC

VOL +

VOL -



0

8

Internal conversion from voltage to show which button has been pressed. See ,

Coolant Fluid Level Sw

Inactive

ACTIVE

0

1

The sensor opens the circuit to ground when the coolant level is low.



Washer Fluid Level Sw

Inactive /

ACTIVE

0

1

The sensor opens the circuit to ground when the washer fluid level is low.



Front Lamp Failure

NO /

YES

0

1

The SID unit energizes the filament monitor which grounds this input if any of the front lamps is faulty.



SID Buttons

NONE

C-

C+

NIGHT PANEL

TRIP UP

TRIP DOWN

SET

CLEAR

0

128

The buttons on the SID unit can be read with this command. See .

Horn Button

Off

On

0

1

The horn button value from the steering wheel converted from voltage to show whether the button was pressed ON/OFF. See for reading voltages from sensors.

Parking Heater

Off

On

0

1

If the parking heater is connected as an accessory, the input from the clock (timer) can be read. For this type of connection, the SID unit must be programmed in order for it to control the function.

Month

MONTH

1

12

The SID unit contains a real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .

Day



1

31

The SID unit contains a real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .

Hour



0

24

The SID unit contains a real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .

Minutes



0

60

The SID unit contains a real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .

Seconds



0

60

The SID unit contains a real-time clock which keeps a record of the day, month, hour, minute and second.

To set the clock, see .

Key Not Accepted Message

Inactive/

ACTIVE

0

1

The request to show the message comes from TWICE. It can be disabled with DICE.



Days Until Service

Days

0

365

Shows the number of days remaining until service.