SAAB WIS ONLINE

PRE-RELEASE

DTC B260B or B260C

DTC B260B or B260C

Diagnostic Instructions


Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

Review Strategy Based Diagnosis for an overview of the diagnostic approach.

Diagnostic Procedure Instructions provides an overview of each diagnostic category.


DTC Descriptor

DTC B260B 01

Left Daytime Running Lamp Relay Control Circuit Short to Battery

DTC B260B 02

Left Daytime Running Lamp Relay Control Circuit Short to Ground

DTC B260B 04

Left Daytime Running Lamps Control Circuit Open

DTC B260C 01

Right Daytime Running Lamp Relay Control Circuit Short to Battery

DTC B260C 02

Right Daytime Running Lamp Relay Control Circuit Short to Ground

DTC B260C 04

Left Daytime Running Lamps Control Circuit Open

Diagnostic Fault Information

Circuit Short to Ground Open/High Resistance Short to Voltage Signal Performance
Left Daytime Running Lamp Relay B+ B260B 04 B260B 04 - -
Right Daytime Running Lamp Relay B+ B260C 04 B260C 04 - -
Left Daytime Running Lamp Relay Control B260B 02 B260B 04 B260B 01 -
Right Daytime Running Lamp Relay Control B260C 02 B260C 04 B260C 01 -
Daytime Running Lamp Relay Control 2 2 1 -
1. The appropriate Park Lamp/Side Marker Lamp is Always ON 2. The appropriate Park Lamp/Side Marker Lamp is Always OFF


Circuit/System Description

The headlamp switch is supplied with ground at all times. When the headlamp switch is placed in either the park or low beam position, ground is applied to the tail lamp signal circuit to the body control module (BCM). The BCM responds by applying battery voltage to the left/right park lamps, left/right side marker lamps and left/right tail lamps. This energizes the appropriate lamp.

Conditions for Running the DTC


Engine is running.

Headlamp switch in AUTO position.

The ambient light is day.


Conditions for Setting the DTC

B260B 01 or B260C 01

The BCM detects a short to voltage on the daytime running lamp relay control circuit.

B260B 02 or B260C 02

The BCM detects a short to ground on the daytime running lamp relay control circuit.

B260B 04 or B260C 04

The BCM detects an open/high resistance on the daytime running lamp relay control circuit.

Action Taken When the DTC Sets

B260B 01 or B260C 01

The appropriate daytime running lamp will be continuously illuminated.



B260B 02, B260C 04, B260B 02 or B260C 04

The appropriate daytime running lamp will be inoperative.

Conditions for Clearing the DTC


The DTC will be current for as long as the fault is present.

When the fault is no longer present, the DTC will be a history DTC.

A history DTC will clear after 50 ignition cycles.


Reference Information

Schematic Reference

Exterior Lights Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Exterior Lighting Systems Description and Operation

Electrical Information Reference


Circuit Testing

Connector Repairs

Testing for Intermittent Conditions and Poor Connections

Wiring Repairs


Scan Tool Reference

Control Module References

Circuit/System Verification

Ignition ON, command the Left Dedicated Daytime Running Lamp and the Right Dedicated Daytime Running Lamp ON and OFF with a scan tool. The E4C daytime running lamp - left and the E4D daytime running lamp - right should turn ON and OFF while changing between the commanded states.

Circuit/System Testing


1. Ignition OFF, disconnect the appropriate KR42 daytime running lamp relay.

2. Ignition ON, verify that a test lamp illuminates between the B+ circuit terminal 86 and ground.

3. If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance.

4. Connect a test lamp between the B+ circuit terminal 86 and the control circuit terminal 85.

5. Command the appropriate Front Park Lamp test with a scan tool. The test lamp should turn ON and OFF when changing between the commanded states.

6. If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the K9 BCM.

7. If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K9 BCM.

8. If all circuits test normal, test or replace the KR42 daytime running lamp relay.


Component Testing


Relay Test

1. Ignition OFF, disconnect the appropriate KR42 daytime running lamp relay.

2. Test for 60-180 Ω between terminals 85 and 86.

3. If not within the specified range, replace the KR42 daytime running lamp relay.

4. Test for infinite resistance between the following terminals:

30 and 86

30 and 87

30 and 85

85 and 87

5. If not the specified value, replace the KR42 daytime running lamp relay.

6. Install a 15A fused jumper wire between relay terminal 85 and 12 V. Install a jumper wire between relay terminal 86 and ground. Test for less than 2 Ω between terminals 30 and 87.

7. If greater than the specified range, replace the KR42 daytime running lamp relay.


Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.


Headlamp Replacement (T84 T85) Headlamp Replacement (TT6 HID)

Relay Replacement (Attached to Wire Harness) Relay Replacement (Within an Electrical Center)

Control Module References for BCM replacement, setup, and programming


PRE-RELEASE