SAAB WIS ONLINE

PRE-RELEASE

P0216

Read the instructions below then start the fault diagnostic procedure.

Symptom: CHECK ENGINE. Engine turns off.

P0216


EDU (powerstage fuel injectors), Malfunction.


Fault symptoms


CHECK ENGINE.

Engine turns off.


On-Board Diagnostics

Type of diagnosis:


- Continuous. But interrupted when fault criteria fulfilled and will not restart until next driving cycle.


Enable criteria:


- Engine running.

- Battery voltage should be greater than or equal to 11 V.


Fault criteria:


- The diagnosis has detected an electrical fault in the wiring harness between the control module, the power stage and the injectors.


Dependents:


- None.


System reaction to a fault:


- Engine turns off.


OK report:


- Fault criteria not fulfilled.


Fault handling:


- CHECK ENGINE lights in first driving cycle.


Diagnostic help

Activate nozzles. NB! Make sure there are no open circuits or short circuits to ground/B+ in the communication cable between the control module and the power stage before activating. The power stage can be damaged if activation takes place in these circumstances.

For more information on DTCs and wiring faults concerning the power stage, see Power stage, DTCs/cable faults .

See also description of read value under "Read Values" menu for more information.

Checking the wiring

Jiggle the wiring harness at several points and in different directions to detect intermittent breaks and short circuits. Observe the multimeter, diagnostic tool or test lamp during the check.

PRE-RELEASE